0020112600_02-10/12-Glow-worm
- 16 -
INSTALLATION
b
Only ue accessories supplied by Glow-worm
must be used.
Differentueoutletcongurationscanbecarriedout.
• Consultyoursupplierformoreinformationabouttheother
possibilitiesandassociatedaccessories.
44 mm/m
1 2
4 3
• Standardueterminalkitshaveanin-builtfallbacktothe
boilertodrainthecondensate.Thesecanbettedlevel
betweentheapplianceandtheterminationposition.Allother
extendeduesmusthaveafallofatleast44mm/m
Themaximumlengthoftheueoutletisdenedaccordingtoits
type(forexampleC13).
• Whateverthekindofuesystemchosen,observethe
minimumdistancesindicatedinthechartbelowtoposition
theueterminals.
• Toinstalltheue,refertotheseparateueinstruction
suppliedwithyourappliance.
• Explaintheserequirementstotheuseroftheappliance.
a
If necessary, you must install a terminal
protection kit.
b
Caution! The connection between the ue elbow
and the ue outlet must be sealed.
theminimumacceptablesitingdimensionsforthe
terminalfromobstructions,otherterminalsandventilation
openingsareshownindiagramoverleaf.
theminimumdistancesforueterminalpositioningmust
bethosedetailedinI.S.813“DomesticGasInstallations”.
Theterminalmustbeexposedtotheexternalair,allowingfree
passageofairacrossitatalltimes.
Beingacondensingboilersomeplumingmayoccurfrom
theueoutlet.Thisshouldbetakenintoconsiderationwhen
selectingthepositionfortheterminal.
Carportsorsimilarextensionsofaroofonly,oraroofandone
wall,requirespecialconsiderationwithrespecttoanyopenings,
doors,ventsorwindowsundertheroof.Careisrequired
toprotecttheroofifmadeofplasticsheeting.Ifthecarport
comprisesofaroofandtwoormorewalls,seekadvicebefore
installingtheboiler.
b
If the ue terminal is positioned near a light
source insects may enter the ue system.
Where safe and practical to do so advise the
homeowner to check the ue outlet and clear
visible insects from the terminal end.