85
MDE-LEDI-1099V3.4
► 4 beeps every hour
Four 200-ms impulses are generated at the end of each hour.
► Six beeps every hour or half-hour
Five 100-ms impulses are generated at the end of each hour or half-hour.
followed by a 300-ms impulse.
B. Temperature option
C. Beep option + temperature option
100 ms
20:59:57 20:59:5920:59:58 21:00:0020:59:5520:59:54 20:59:56
300 ms
200 ms
20:59:57 20:59:5920:59:58 21:00:0020:59:56
Temperature option
Alternation time for
temperature display
+ / -
Duration of temperature display (in seconds)
Set to 0 if you don't want to display
PROG
Beep option +
Temperat ure option
Beep sett ing
+ / -
OFF: no beep
4t 0t: 4 beeps every ho ur
6t 0t : 6 beep s every hou r
6t 6t : 6 beep s every ½ hour
PROG
Temperature offset setting
+ / -
-0°1
: - 0.1°C offset
0°0
: No temperature OFFSET
0°1
: 0.1°C offset
.. .
PROG
ENGLISH