EasyManua.ls Logo

Graco PR70 - User Manual

Graco PR70
82 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
Loading...
312759W
EN
Operation - Maintenance
PR70
and PR70v
with Advanced Display Module
Fixed or variable ratio systems. For accurate metering, mixing, and dispensing of
two-component materials. For professional use only.
Not approved for use in European explosive atmosphere locations.
3000 psi (21 MPa, 207 bar) Maximum Working Pressure
100 psi (0.7 MPa, 7 bar) Maximum Air Inlet Pressure
Important Safety Instructions
Read all warnings and instructions in all sup-
plied manuals. Save these instructions.
PR70v Shown with Advanced Display Module
ti12385b

Other manuals for Graco PR70

Questions and Answers

  • D
    Danielle WardSep 18, 2025
    What to do if Graco Music Mixer display module is completely dark?
    • J
      Jenny ConleySep 18, 2025
      If the display module on your Graco Music Mixer is completely dark, check these items: * Ensure the rear AC Power switch is ON. * Replace the machine fuses if they are blown. * Tighten the cable on the Display Module if there is a loose connection. * Replace the Display Module if it is bad.
  • D
    Darren MooreAug 25, 2025
    What does error code E24 mean on Graco PR70 Dispenser?
    • A
      Ariana SandersAug 25, 2025
      If you receive an E24 Improper Calibration Error on your Graco Dispenser, it indicates that the machine's calibration is invalid, preventing the requested shot from being executed. To resolve this, correct the calibration on the machine.
  • E
    escottAug 25, 2025
    Why is the material dispensed from my Graco Dispenser not the correct weight?
    • B
      brownnicholasAug 26, 2025
      If the Graco Dispenser is dispensing material that is not the correct weight, first, recalibrate the machine if the specific gravity of the materials has changed or if the air pressure has changed since the last calibration. Also, ensure there is enough material in the tanks, filling and priming as needed. If there's a slight obstruction in the mixer, replace it and prime the machine. Finally, inspect the check valve for malfunctions, cleaning or replacing it if necessary, and replace the piston if it's worn or broken.
  • T
    Tracy WatkinsAug 27, 2025
    What to do if my Graco PR70 is dispensing off ratio?
    • A
      Amy DoyleAug 27, 2025
      If your Graco Dispenser is dispensing off ratio, start by checking the tank levels and adding material if necessary. Ensure the tank ball valve is open and prime the machine. If the machine is out of phase, rephase it. Also, check the valve for any malfunctions, and clean or replace it as needed. Finally, replace the piston if it's worn or broken.
  • S
    Steven CortezSep 19, 2025
    How to resolve no material dispensed from Graco Music Mixer?
    • T
      Tina HendricksSep 22, 2025
      If there is no material dispensed or an incorrect amount from either side of your Graco Music Mixer, check the following: * Open the tank ball valve if it is closed. * Fill the tank with material if it is empty. * Verify there is no obstruction in the tank if it is clogged. * Prime the machine until the air is removed if there is air in the material. * Remove, clean, or replace the check valve if it malfunctions. * Remove and replace the piston if it is worn.
  • W
    Walter BerrySep 23, 2025
    What causes significant material leaking from Graco Music Mixer pump rear seal?
    • R
      Rodney SmithSep 23, 2025
      Significant material leaking from the pump rear seal of your Graco Music Mixer is caused by a worn pump shaft and/or shaft seal. To resolve this, remove the pump shaft assembly and reinstall the rear pump rebuild kit.
  • A
    alyssa38Sep 9, 2025
    How to fix a stalled piston in Graco PR70?
    • J
      John LeblancSep 10, 2025
      If the piston in your Graco Dispenser is stalled: * Check if the input air is reduced or removed. Reconnect the input air line to the machine and increase the air pressure regulator adjustment. * The mixer could be blocked. Replace the static mixer, and incorporate a purge timer or decrease the purge timer delay to prevent future blockages. * The Open Dispense Valve (ODV) adjustment might be too late. Readjust the ODV setting to occur sooner. * A check valve might be blocked. Remove, clean, and replace the check valve. * There might be an air cylinder failure. Remove the air cylinder and reinstall the air cylinder parts as necessary.
  • V
    Victoria HolmesSep 12, 2025
    What to do if Graco PR70 Dispenser is not dispensing material?
    • D
      Debbie DavisSep 12, 2025
      If your Graco Dispenser is not dispensing material or dispensing an incorrect amount, check the following: * Ensure the tank ball valve is open (if installed). * Verify that the tank is not empty and fill it with material if needed. * Check the tank for any obstructions. * Prime the machine to remove any air in the material. * Inspect the check valve for malfunction; remove, clean, or replace it. * Check the piston for wear or breakage; remove and replace it if necessary.
  • J
    Jennifer NelsonSep 3, 2025
    What causes a piston to stall in a Graco PR70 and how to fix it?
    • M
      Matthew FosterSep 3, 2025
      If the piston on your Graco Dispenser is stalled, it could be due to several reasons. First, check if the input air is reduced or removed; reconnect the air line and increase the air pressure regulator adjustment. A blocked mixer can also cause this, so replace the static mixer and consider using a purge timer to prevent future blockages. An improperly adjusted Open Dispense Valve (ODV) might be the issue, so readjust the ODV setting. Additionally, a blocked check valve can cause the piston to stall, so remove, clean, and replace it. Finally, an air cylinder failure could be the cause, so remove and reinstall the air cylinder parts as needed.
  • A
    allendwayneSep 1, 2025
    What to do if my Graco PR70 Dispenser is not dispensing the correct amount of material?
    • A
      Anita ParksSep 1, 2025
      If the Graco Dispenser isn't dispensing material, or the amount is incorrect, there might be several reasons. First, ensure the tank ball valve is open. Next, check if the tank is empty or clogged. If not, there may be air in the material, so prime the machine to remove it. A malfunctioning check valve may also be the cause; try removing, cleaning, or replacing it. Lastly, a worn or broken piston can cause this issue, so remove and replace the piston if necessary.

Summary

Product Configurator

Warnings

ELECTRIC SHOCK HAZARD

Hazards related to electrical shock during operation.

SKIN INJECTION HAZARD

Risks of high-pressure fluid injection and necessary precautions.

TOXIC FLUID OR FUMES HAZARD

Dangers from toxic fluids and fumes, requiring safety measures.

PERSONAL PROTECTIVE EQUIPMENT

Essential protective gear for safe operation and maintenance.

FIRE AND EXPLOSION HAZARD

Risks of flammable fumes igniting or exploding in the work area.

EQUIPMENT MISUSE HAZARD

Dangers and injuries resulting from improper equipment operation.

MOVING PARTS HAZARD

Risks of injury from moving mechanical components during operation.

BURN HAZARD

Danger of severe burns from hot equipment surfaces or fluids.

Moisture Sensitivity of Isocyanates

Component Identification

Advanced Display Module (ADM)

Screen Navigation Diagram

Grounding

Installation

Machine Installation

Steps for physically mounting the machine and connecting utilities.

Electrical Requirements

Necessary electrical power and wiring considerations for installation.

Ground System

Importance and procedure for grounding the equipment for safety.

Startup

Setup

Setup Screens

Overview of the different setup screen categories.

Calibration Screen

Screen for performing various calibration procedures.

Options Screens

Screens for configuring fluid and system options.

Heat Options, Screen #2

Settings for tank and hose heater temperature control.

System Options, Screen #3

Configuring general system behavior and run screen options.

Dispense Check Options, Screen #4

Settings for monitoring dispense accuracy.

Piston Position Calibration

Calibrating the piston's extended and retracted positions.

Extended Piston Position

Procedure to set the extended position of the piston.

Retracted Piston Position

Procedure to set the retracted position of the piston.

Engaged Piston Position

Procedure to set the piston position when engaging the cylinder.

Prime the Dispense Head

Procedure to fill the dispense head with material and remove air.

Phasing Adjustment

Adjusting the timing of material delivery for correct ratio.

Adjust Dispense Quantity

Fine-tuning the dispense amount for accurate phasing.

Adjust Phasing

Detailed steps for adjusting material phasing.

Adjust Dispense Valve Snuff Back

Adjusting the valve to prevent material drip or air intake.

Adjust Open Dispense Valve (ODV) Timing

Setting the timing for the dispense valve opening.

Calibrate Dispense Weight Ratio (PR70 v only)

Calibrating the machine for accurate dispensing ratios.

Perform Weight Ratio Check Shot

Performing shots to verify and adjust the dispensing ratio.

Shot Calibration

Performing small and large shots to calibrate dispensing quantities.

Perform Small Calibration Shots

Executing and recording small calibration shots.

Perform Large Calibration Shots

Executing and recording large calibration shots.

Flow Meter Calibration, Screen #5

Calibrating flow meters for accurate ratio.

Perform Flow Meter Calibration Shot

Executing shots to measure and record flow meter data.

External Control Interface Setup

Connecting and configuring external machine controls.

Operation

Operation Screens

Overview of the main operational screens.

Error Screens

Viewing a log of system errors.

Auto-Refill

Configuring and initiating automatic tank refilling.

Temperature Control

Managing tank and hose heater temperatures.

USB Data

Pressure Relief Procedure

Shutdown

Maintenance

Schedule

Recommended maintenance tasks and their frequencies.

Troubleshooting

Error Codes

System Behavior Descriptions

Technical Data

Graco PR70 Specifications

General IconGeneral
Hose LengthCustomizable
Power SourceElectric
Ratio Range1:1 to 12:1
Viscosity RangeUp to 1, 000, 000 cps
MaterialsEpoxies, polyurethanes, silicones, and other two-component materials
ApplicationsPotting, encapsulation, gasketing, sealing, bonding
Dispensing CapacityVariable, based on configuration
WeightApproximately 150 lbs
DimensionsVaries based on configuration

Related product manuals