EasyManua.ls Logo

Graco REACTOR E-XP2

Graco REACTOR E-XP2
80 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Spraying
Calibration Calibration
Calibration
Procedure Procedure
Procedure
NOTICE NOTICE
NOTICE
Topreventdamagetotheheatedhose,ahose
calibrationisrequiredifanyofthefollowing
conditionsaretrue:
Thehosehasneverbeencalibratedbefore.
Asectionofhosehasbeenreplaced.
Asectionofhosehasbeenadded.
Asectionofhosehasbeenremoved.
NOTE: NOTE:
NOTE:
TheReactorandheatedhosemustbeat
thesameambienttemperaturetogetthemost
accuratecalibration.
1.EnterSetupModeandnavigatetoSystem
screen3,thenpresstheCalibratesoftkey
.
2.PresstheContinuesoftkeyto
acknowledgetheremindertohavethehose
atambientconditions.
3.Waitwhilethesystemmeasuresthehose
resistance.
NOTE: NOTE:
NOTE:
Ifhoseheatwasonpriortothe
calibrationprocedure,thesystemwill
waituptoveminutestoallowthewire
temperaturetoequalize.
NOTE: NOTE:
NOTE:
Thehosetemperaturemustbeabove
32°F(0°C)duringcalibration.
56 333023U

Table of Contents

Other manuals for Graco REACTOR E-XP2

Related product manuals