Basic Settings and Operations
3-5
Setting QUALITY
Sets the acceleration used in cutting.
(1) Press the (COND.) key in READY mode to display the cutter-pen conditions.
(2) Select the setting area (condition number) to be set, and then use the or key to move
the s symbol to the position shown below.
2 09U +1 23 30 2
(3) Press the or key to select the value to be changed in the range specified below
"1", "2", "*"
Press the (ENTER) key to confirm the selection. If other conditions are to be set, press the
or key to move the s symbol to the parameter to be set.
CHECKPOINT
If SPEED is set to "*", QUALITY is also set to "*" and acceleration is calculated automatically.