Function Settings and Operations
4-31
4.27 User-specified Settings
This function loads the user-specified (CAD) settings. The COMMAND, ORIGIN POINT or STEP SIZE, RS-
232C TRANSMISSION CONDITIONS, SEPARATOR, TIMEOUT and PAGE LENGTH settings are set here.
(1) Press the (PAUSE) key to switch to PAUSE mode.
(2) Press the (NEXT) or
(PREV.) key until the following menu is displayed.
SETUP MENU
(3) Press the (ENTER) key, and then press the (NEXT) or (PREV.) key
until the following menu is displayed.
SELECT USER
(4) Press the
(ENTER) key to display the USER SETTINGS setting.
SELECT USER 1
Press the or key to specify a setting from "1" through "8", and then press
the (ENTER) key. To cancel the selection, press the
(NEXT) or
(PREV.) key.
(5) Press the
(PAUSE) key to cancel PAUSE mode.
BLADE WARE SETUP
CUT LINE PAT.
TANGENTIAL
INIT. B
PEN UP SPEED
INITIAL FEED
TEST
FEED&CUT
PEN UP/DOWN
CLEAR BUFFER
AUTO PRE FEED
ADVANCED FUNC.
SETUP MENU
CAD 1 2345678
COMMAND HP-GL HP-GL GP-GL HP-GL HP-GL HP-GL HP-GL HP-GL
STEP SIZE 0.025 0.025 0.025 0.025 0.025 0.025 0.025 0.025
ORIGIN POINT
L.L. Center L.L. L.L. L.L. Center Center Center
SEPARATOR PG NR J0 SP PG SP None None
TIMEOUT 0 0 120 120 120 10 0 0
PAGE LENGTH
1500 3000 1500 5000 5000 1500 5000 5000
(mm)
TRANSMISSION
9600, 9600, 9600, 9600, 9600, 19200, 9600, 9600,
CONDITIONS
N81X N81X N81X N81X N81X N81X N81X N81X