Function Settings and Operations
4-7
(2) Press the (NEXT) or (PREV.) key until the following menu is displayed.
BLADE WEAR SETUP
(3) Press the (ENTER) key to display the wear-rate setting submenu, and
then press the (NEXT) or (PREV.) key until the following menu is
displayed.
CLEAR GROUP
(4) Press the (ENTER) key to display the wear-rate clear menu.
CLR GROUP1 <YES>
(5) The number to the right of "CLEAR GROUP" is the group number. Use the or
key to increase or decrease the group number, and press the or key to
select "YES" or "NO." Select "YES" for the group number to be cleared, and press
the (ENTER) key to clear the total distance. To cancel the selection(s), press the
(NEXT) or (PREV.) key.
(6) Press the (PAUSE) key to cancel PAUSE mode.