8.3.4 Setting to minimum speed
The motor must not be in operating mode Stop.
Press and hold the Down button until the bottom
light field is on and starts flashing.
H
Q
TM054897
8.3.5 Starting the pump
How you start the pump depends on how it was
stopped.
Start the pump in one of the following ways:
- If the pump was stopped by pressing the Start/
Stop button: Start the pump by pressing the
Start/Stop button.
- If the pump was stopped by pressing and
holding the Down button: Start the pump by
pressing and holding the Up button.
8.3.6 Stopping the pump
Stop the pump in one of the following ways:
- Press the Start/Stop button.
- Press and hold the Down button until all light
fields are off.
- Use Grundfos GO.
- Use a digital input set to External stop.
8.3.7
Resetting alarms and warnings in products
with the HMI 200 or 201 operating panel
You can reset a fault indication in one of the
following ways:
- Briefly press the Up or Down button.
This is not possible if the buttons have been
locked.
This does not change the setting of the motor.
- Switch off the power supply until the indicator
lights are off.
- Switch the external start and stop input off, and
then on again.
- Use Grundfos GO.
- Use the digital input if you have set it to Alarm
resetting.
35
English (GB)

Table of Contents

Other manuals for Grundfos CRE Series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Grundfos CRE Series and is the answer not in the manual?

Grundfos CRE Series Specifications

General IconGeneral
Motor TypeAsynchronous
Enclosure ClassIP55
Insulation ClassF
SeriesCRE
Protection ClassIP55
MaterialStainless Steel
ApplicationsWater Supply, Pressure Boosting, Irrigation
Pumped liquidClean liquids
ApprovalsCE
Voltage380-415V
Connection SizeDN 32 to DN 100
EfficiencyIE3 Premium Efficiency
Power Supply3-phase
Liquid Temperature Range-10°C to +120°C
Temperature Range-10°C to +120°C

Related product manuals