EasyManuals Logo

Grundfos CRE Series User Manual

Grundfos CRE Series
99 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #88 background imageLoading...
Page #88 background image
Model K
Motor
[kW]
Emission category
1450-2200 rpm 2900-4000 rpm 3500-4000 4000-5900 rpm
11
C2/C3
14)
- - -
15
C2/C3
14)
C2/C3
14)
- -
18.5
C2/C3
14)
C2/C3
14)
- -
22
C2/C3
14)
C2/C3
14)
- -
26 - -
C2/C3
14)
-
14)
Depending on product hardware configuration.
13.4.3 Enclosure class
Standard: IP55.
Optional: IP66.
IP ratings are evaluated in accordance with IEC 60034-5.
The IP rating can be found on the product's nameplate:
OUTPUT Variant
V
Hz
A
P2:
PB:
FM:
HMI:
CIM:
kW
rpm
%
n:
PDS Eff
xxxv
:
98100448
IE5
IES2
Type:
P.N.:
DE:
-V
kg
NDE:
Wt:
P.C.:
Type:
IP:
U in:
f in:
I1/1:
CL:
˚C
˜
Made in Hungary
DK - 8850 - Bjerringbro - Denmark
TM084099
13.4.4 Insulation class
311 °F (155 °C).
13.4.5 Standby power consumption
5-10 W.
13.4.6 Cable entry sizes
Number and size of cable entries
Model K
Motor
[kW]
1450-2200 rpm 2900-4000 rpm 3500-4000 rpm 4000-5900 rpm
11 1 × M40 + 6 × M20 - - -
15 - 22 1 × M40 + 6 × M20 1 × M40 + 6 × M20 - 1 × M40 + 6 × M20
26 - - 1 × M40 + 6 × M20 -
88
English (GB)

Table of Contents

Other manuals for Grundfos CRE Series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Grundfos CRE Series and is the answer not in the manual?

Grundfos CRE Series Specifications

General IconGeneral
Motor TypeAsynchronous
Enclosure ClassIP55
Insulation ClassF
SeriesCRE
Protection ClassIP55
MaterialStainless Steel
ApplicationsWater Supply, Pressure Boosting, Irrigation
Pumped liquidClean liquids
ApprovalsCE
Voltage380-415V
Connection SizeDN 32 to DN 100
EfficiencyIE3 Premium Efficiency
Power Supply3-phase
Liquid Temperature Range-10°C to +120°C
Temperature Range-10°C to +120°C

Related product manuals