Loading...
REMOTE CONTROL
89
Sequence Commands
[:SOURce]:SEQuence:CPARameter ................. 89
[:SOURce]:SEQuence:CSTep ............................. 90
[:SOURce]:SEQuence:SPARameter .................. 90
[:SOURce]:SEQuence:STEP ............................... 91
:TRIGger:SEQuence:SELected:EXECute ......... 92
[:SOURce]:SEQuence:CPARameter
Set
Sets the common parameters for the Sequence
mode. Please see the user manual for a full
description of each parameter.
[:SOURce]:SEQuence:CPARameter
{<NR2>,<NR2>,<bool>|OFF|ON,<NR2>,<bool>|OFF|
ON,<NR1>|CONTinue|END|HOLD,<NR1>,<bool>|OF
F|ON,<NR1>,<bool>|OFF|ON,<NR1>,<bool>|OFF|O
N,<NR1>,<bool>|OFF|ON,<bool>|OFF|ON}
[:SOURce]:SEQuence:CPARameter?
<NR2>
Step Time
<NR2>
On phase
<bool>|OFF|ON|FR
EE|FIXED
On phase off (free)(1) / on
(fixed)(0)
<NR2>
Off phase
<bool>|OFF|ON|FR
EE|FIXED
Off phase off (free) / on (fixed)
<NR1>|CONTinue|
END|HOLD
Term settings:
Continue(1)/End(2)/Hold(3)
<NR1>
Jump step number (0 ~ 999)
<bool>|OFF|ON
Jump on(1)/off(0)
<NR1>
<NR1>
Jump Cnt (0~ 9999)
Sync Code: LL(0) / LH(1) / HL(2)
/ HH(3)
<NR1>
Branch1 (0 ~ 999)
<bool>|OFF|ON
Branch1 on(1)/off(0)
<NR1>
Branch2 (0 ~ 999)
<bool>|OFF|ON
Branch2 on(1)/off(0)