EasyManua.ls Logo

GW Instek ASR-2000 Series - Page 92

GW Instek ASR-2000 Series
125 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
ASR-2000 Programming Manual
92
:TRIGger:SEQuence:SELected:EXECute
Set
Query
Description
Sets to execute actions for sequence mode
Syntax
:TRIGger:SEQuence:SELected:EXECute
{STOP|STARt|HOLD|BRAN1|BRAN2}
Parameter
STOP
Stops sequence execution
STARt
Starts sequence execution
HOLD
Holds sequence execution
BRAN1
Jumps to Branch 1 execution
BRAN2
Jumps to Branch 2 execution
Example
TRIG:SEQ:SEL:EXEC STAR
Starts sequence execution.

Table of Contents

Other manuals for GW Instek ASR-2000 Series