EasyManua.ls Logo

GW Instek GDS-1102B - Trigger:video:field

GW Instek GDS-1102B
168 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
GDS-1000B Programming Manual
128
Parameter
NTSC
NTSC
PAL
PAL
SECam
SECAM
EDTV480P
Extra definition TV 480P
EDTV576P
Extra definition TV 576P
HDTV720P
High definition TV 720P
HDTV1080I
High definition TV 1080i
HDTV1080P
High definition TV 1080P
Return parameter
Returns the video trigger type.
Example
:TRIGger:VIDeo:TYPe NTSC
Sets the video trigger to NTSC.
:TRIGger:VIDeo:FIELd
Description
Sets or queries the video trigger field.
Syntax
:TRIGger:VIDeo:FIELd { FIELD1 | FIELD2 | ALLFields |
ALLLines | ? }
Related
commands
:TRIGger:TYPe
Parameter
FIELD1
Trigger on field 1
FIELD2
Trigger on field 2
ALLFields
Trigger on all fields
ALLLines
Trigger on all lines
Return parameter
Returns the video trigger field.
Example
:TRIGger:VIDeo:FIELd ALLFields
Sets the video trigger to trigger on all fields.
Set
Query

Table of Contents