COMMAND DETAILS
61
:CURSor:VUSE
Description
Sets the current cursor position as the ratio
reference for the Percent (vertical) cursors.
Note
This command can only be used when
:CURSor:VUNI is set to PERcent.
Syntax
:CURSor:VUSE {CURRent}
Related
Commands
:CURSor:MODe
:CURSor:VUNI
Parameter
CURRent
Uses the current vertical position
Example
:CURSor:VUSE CURRent.
:CURSor:DDT
Description
Returns the deltaY/deltaT (dy/dT) readout. This
function is only supported if the source channels
are CH1~4, Ref1~4 or Math.
Syntax
:CURSor:DDT{?}
Related
Commands
:CURSor:MODe
Return Parameter
<NR3>
Returns the readout in <NR3> format.
Example
:CURSor:DDT?
4.00E-05
:CURSor:H1Position
Description
Sets or returns the first horizontal cursor (H1)
position.
Syntax
:CURSor:H1Position {<NRf>| ?}
Related
Commands
:CURSor:H2Position
Set
Query
Set
Query

Table of Contents