COMMAND DETAILS
85
Related
Commands
:MEASure:SOURce<X>
Return parameter
<NR3>
Returns the overshoot.
Chan Off
Indicates the source channel is not
activated.
Note
Before using this command, select the
measurement channel. See the example below.
Example
:MEASure:SOURce1 CH1
:MEASure:ROVShoot?
5.00E+00
Selects Channel 1, and then measures the rise
overshoot.
:MEASure:RPReshoot
Description
Returns rising preshoot over the entire waveform
in percentage.
Syntax
:MEASure:RPReshoot{?}
Related
Commands
:MEASure:SOURce<X>
Return parameter
<NR3>
Returns the rising preshoot.
Chan Off
Indicates the source channel is not
activated.
Note
Before using this command, select the
measurement channel. See the example below.
Example
:MEASure:SOURce1 CH1
:MEASure:RPReshoot?
2.13E-2
Selects Channel 1, and then measures the rise
preshoot.