REMOTE CONTROL
133
Function
Queries the delay parameter of the specified groups
of Delay. Returns to a string initiating from #. Data
head is to describe data length information starting
from #. For example, ##9000000017, the later 9
digits (000000017) following the initial 9 indicate
length of data flow (17 bytes).
The format of sequence parameter of each group is
“serial number, output state, delay duration, and
parameter of each group is divided by
semicolon“;”.
For example: 2, OFF, 3;3, ON,1;” representing the
delay parameters of 2 groups; the serial number of
delay parameter of the 1
st
group is 2, output state is
OFF,delay time is 3S;the 2
nd
group is 3, output state is
ON,delay time is 1S.
Description
<No> 0 2047 Sets the serial number of the delay
parameter. Integer 0 - 2047
Example
:DELAy2:PARAmeter? 2,2
Return the delay parameter of 2 groups of Delay
for CH2. From the second group.
Command
:DELAy[1|2]:STARt <value>
Function
Sets the sequence number for initial execution.
<value>: Integer 0 - 2047
Description
:DELAy2:STARt 10
Sets the CH2 sequence output to start from the group 10.
Command
:DELAy[1|2]:STARt?
Function
Queries the sequence number for initial execution of
the channel delay output.