REMOTE CONTROL
141
Command
:MONItor[1|2|3|4] [:STATe] {ON|OFF}
Function
Enable or disable monitor (active channel)
Example
:MONItor2 ON
Enable monitor for CH2
Command
:MONItor[1|2|3|4][:STATe]?
Function
Queries whether the current monitor is On or Off
(active channel).
Example
:MONItor2?
Queries whether the current monitor is On or Off of
CH2. Returns to ON or OFF.
Command
:MONItor[1|2|3|4]:STOPway {OUTOFF|ALARM
|BEEPER},{ON|OFF}
Function
Sets the stop method of monitor (active channel).
Description
{OUTOFF|ALARM |BEEPER} Disable output by
set stop method (OUTOFF), warning (ALARM) or
beep (BEEPER).
Example
:MONItor2: STOPway ALARM,ON
Enable stop method of “warning” for CH2.
Command
:MONItor[1|2|3|4]:STOPway?
Function
Queries the stop method for current monitor (active
channel).
Example
:MONItor2:STOPway?
Queries the CH2 stop method state of current
monitor. Returns to the on & off state of the 3 stop
methods.