Example
:SYSTem:COMMunicate:LAN:MANualip ON
Enables a manual IP address to be set.
Command
:SYSTem:COMMunicate:LAN:MANualip[:STATe]?
Function
Queries whether manual IP addressing has been
enabled or disabled.
Example
:SYSTem:COMMunicate:LAN:MANualip?
Queries the status of the manual IP addressing.
Command
:SYSTem:COMMunicate:LAN:APPLy
Function
When this command is executed, all the LAN
settings are applied.
Example
:SYSTem:COMMunicate:LAN:APPLy
Applies all the LAN settings.
Command
:SYSTem:REMote
Function
Sets the unit to remote control.
Example
:SYSTem:REMote
Sets to remote control mode
Command
REMOTE
Function
Sets the unit to remote control.
Example
REMOTE
Command
:SYSTem:BEEPer:STATe <b>
Function
Turn the buzzer on or off.
<b>
0/OFF: Turn the buzzer off.
1/ON: Turn the buzzer on.