PARAMETERS
June 1999
96-8000
Z DSBL LS ZTST Used to disable the linear scale Z test.
Z ZERO AXIS TC Used to return axis to zero prior to tool change (VR-series) .
Z 2ND HOME BTN Used to move axis to coordinate specified in Work Offset G129.
Z NEG COMP DIR Used to negate the direction of thermal compensation.
Z DELAY AXIS 0 Used with an APL to ensure Z axis is zeroed before A axis of APL
Z MAX TRAVEL INP This bit is set to 1 on five axes machines. This bit indicates that there
is a switch (visible through MOCON) that detects if the axis has
rotated all the way round. It is used to tell the control to skip the first
zero switch when zeroing so it can unwrap the cables.
Parameter 269 A SWITCHES
Parameter 269 is a collection of single-bit flags used to turn servo related functions on and off.
The left and right cursor arrows are used to select the function being changed. All values are 0
or 1 only. The function names are:
A LIN SCALE EN Used to enable linear scales for the A axis.
A INVRT LN SCL Used to invert the A-axis linear scale.
A DSBL LS ZTST Used to disable the linear scale Z test.
A ZERO AXIS TC Used to return axis to zero prior to tool change (VR-series).
A 2ND HOME BTN Used to move axis to coordinate specified in Work OPffset G129.
A DELAY AXIS 0 Used with an APL to ensure A axis is zeroed before B axis of APL.
A MAX TRAVEL INP This bit is set to 1 on five axes machines. This bit indicates that there
is a switch (visible through MOCON) that detects if the axis has
rotated all the way round. It is used to tell the control to skip the first
zero switch when zeroing so it can unwrap the cables.
Parameter 270 B SWITCHES
Parameter 269 is a collection of single-bit flags used to turn servo related functions on and off.
The left and right cursor arrows are used to select the function being changed. All values are 0
or 1 only. The function names are:
B LIN SCALE EN Used to enable linear scales for the B axis.
B INVRT LN SCL Used to invert the B-axis linear scale.
B DSBL LS ZTST Used to disable the linear scale Z test.
B ZERO AXIS TC Used to return axis to zero prior to tool change (VR-series).
B 2ND HOME BTN Used to move axis to coordinate specified in Work Offset G129.
B DELAY AXIS 0 Used with an APL to ensure B axis is zeroed before A axis of APL.
B MAX TRAVEL INP This bit is set to 1 on five axes machines. This bit indicates that there
is a switch (visible through MOCON) that detects if the axis has
rotated all the way round. It is used to tell the control to skip the first
zero switch when zeroing so it can unwrap the cables.