327
ALARMS
June 1999
96-8000
533 Macro Variable Undefined A conditional expression evaluated to an UNDEFINED value, i.e.
#0. Return True or False.
534 DO Or END Already In Use Multiple use of a DO that has not been closed by and END in the
same subroutine. Use another DO number.
535 Illegal DPRNT Statement A DPRNT statement has been formatted improperly, or DPRNT
does not begin block.
536 Command Found On DPRNT Line A G-code was included on a DPRNT block. Make two separate
blocks.
537 RS-232 Abort On DPRNT While a DPRNT statement was executing, the RS-232
communications failed.
538 Matching END Not Found A WHILE-DO statement does not contain a matching END
statement. Add the proper END statement.
539 Illegal Goto Expression after "GOTO" not valid.
540 Macro Syntax Not Allowed A section of code was interpreted by the control where macro
syntax is not permitted. In lathe controls, PQ sequences
describing part geometry cannot use macro statements in the
part path description.
541 Macro Alarm This alarm was generated by a macro command in a program.
613 Command Not Allowed In Cutter Comp. A command (M96, for example) in the highlighted block cannot
be executed while cutter comp. is invoked.
620 C Axis Disabled Parameters have disabled this axis
621 C Over Travel Range C-axis will exceed stored limits. This is a parameter in negative
direction and is machine zero in the positive direction. This will
only occur during the operation of a user's program.
The following alarms apply only to the the sidemount tool changer on the vertical mills:
622 Tool Arm Fault This alarm supports the serpentine type 1 and the Disk type 1
tool changers. It is generated if the arm is not at the Origin
position, or the arm motor is already on when a tool change
process is started.
623 Side Mount Carousel Error This alarm supports the serpentine type 1 and the Disk type 1
tool changers. It is generated if the carousel motor is still on
when the tool pocket is unlocked and lowered prior to a tool
change.
On the serpentine type 1 tool changer, during tool change
recovery, this alarm is also generated if the carousel does not
start to rotate after the allowed time specified by parameter 60
TURRET START DELAY, or does not stop rotating after the
allowed time specified by parameter 61 TURRET STOP DELAY.