41
Numerate the reading of the densimeter.
CAUTION
The dobber of densimeter must rise
uprightly without depending on the
glass pipe.
2 Measuring the proportion
Use gravimeter to calculate the electrolyte proportion.
3 Conversion of the specific gravity
The specific gravity at the standard temperature of 30
0
C should be converted as follow:
D30= Dt + 0.0007( t - 30 )
Therein toD30 ——the specific gravity at the standard temperature of 30
0
C
Dt ——the specific gravity at the temperature of t0C.
t ——the temperature of the distilled water during convert.
·The specific gravity referred in this book is measured all at the temperature of 30.