Chapter 2 Installing the ProStream 9100
© 2016 Harmonic Inc. All rights reserved. 29 ProStream 9100 Release 17.5, Rev A
Device Dimensions
Handle the card only at an ESD workstation and use anti-static rubber mat and wrist bands.
Handle the IOM with care. Do not touch components and contacts on the board and hold the
board by its edges.
Inserting an IOM/RF card
To insert an IOM card, you need the following:
Phillips screwdriver
ESD-preventing wrist band
ESD-preventing rubber mat
You can insert the card either before or after mounting the device in the rack, according to your
personal preference.
To insert an IOM/RF card:
1. Verify that the device is powered off.
2. Remove the filler panel that covers the required IOM slot.
3. Unpack the IOM card.
4. Hold the card by its edges and insert it into the slot.
Make sure that the sides of the card slide into the guides of the IOM slot.
5. Push the card until its edge-connector mates securely with the connector in the slot.
6. Fasten the screws of the card to secure the IOM card to the chassis.
If you did not mount the device into the rack before inserting the card, mount it now.
Device Dimensions
Dimensions are provided in inches and millimeters as follows:
[inch]