EasyManuals Logo

Hawk Gladiator Manual

Default Icon
32 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #2 background imageLoading...
Page #2 background image
Table of Contents
2
Contents
Overview 3
Principle of Operation 3
Typical Uses 3
Function 3
Features 3
System Components 4
Dimensions 5
Gladiator Remote Amplifier 5
AWRT-JB Junction Box 5
Remote Transducer 6
Mounting Flange 6
Remote Transducer with Spray Cleaner 6
Wiring 7
Gladiator Remote Amplifier 7
AWRT-JB Junction Box 7
Transducer Cable Extension 8
Mounting Dimensions & Instructions 9
Remote Transducer 9
Remote Transducer with Spray Cleaner 9
System Overview 10
GAWC-SYS1 Acoustic Cleaner Components 10
GAWC-SYS2 Acoustic Cleaner Components 11
Mounting Dimensions & Instructions 12
Application Examples 12
User Interface 13
Facia Controls 13
Power Up Sequence 14
Powering The System For The First Time 14
Commissioning 15
Blocked Chute Applications 15
Level Switch Applications 16
Software 17
Displayed Diagnostics 17
Main Menus 18
Quickset Menu 18
App Types 19
App Types 20
Advanced Menu 21
Relay 2 Functions 22
Relay 2 Functions 22
Gain Based Maintenance /
Spray Cleaner Setup Examples 23
Time Based Spray Cleaner Setup Example 23
Transducer Initialization 24
Troubleshooting 25
Error Codes 25
Software Flow Chart 26
Part Numbering 30
Remote Amplifier 30
Remote Transducer 30
Junction Box 30
Extra Cable 30
Mounting Flange 30
Part Numbering / Specications 31
Cleaning System (GAWC-SYS1) 31
Cleaning System Mounting Flange 31
Spray Cleaner Specifications 31
Solenoid coil MD-2-24VDC-PC - #549903 31
Cleaning System (GAWC-SYS2) 31
Specications 32
Gladiator Acoustic Switch Series
Software v7.46 onwards

Other manuals for Hawk Gladiator

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Hawk Gladiator and is the answer not in the manual?

Hawk Gladiator Specifications

Power IconPower
operating voltage12-30VDC, 90-260VAC, 36-60VDC
power consumption<0.8W @ 24VDC, <5VA @ 240Vac, <3VA @ 115Vac
Operating Environment IconOperating Environment
maximum operating pressure2 BAR
operating temperature for remote electronics-40°C (-40°F) to 80°C (176°F)
operating temperature for remote sensors-20°C (-4°F) to 80°C (176°F)
enclosure sealing for remote electronicsIP67 (NEMA 4x)
enclosure sealing for remote sensorsIP68
Weight and Dimensions IconWeight and Dimensions
transducer to amplifier separationUp to 500m (1640ft)
typical weight for 15kHz transducer8 kg
typical weight for remote amplifier1 kg