User manual for single-phase meter
21
10.3 Relay control mode
The default mode is mode 6.
Control
mode
Disconnection
Reconnection
Remote
Manual
Local
Remote
Manual
Local
b
c
f
g
a
d
e
h
0
× × × × × × × ×
1
× × ×
2
× × ×
3
× × ×
4
× × ×
5
× ×
6
× × ×
10.4 Relay operation priority
Open Relay
Operation code
Priority
Balance low, emergency credit
available(only for prepaid mode meter)
01 8
Balance low, emergency credit used(only
for prepaid mode meter)
02
9
Overload
03 5
STS opening test(only for prepaid mode
meter)
04
4
Meter cover open 05 6
Terminal cover open 06 7
Remote open
07 2
Factory default open
0B
10
Close Relay
Normal operation
00
11
STS closing test(only for prepaid mode
meter)
10
3
Remote closing
20
1
Note: Smaller number means higher priority