User manual for single-phase meter
31
under DST setted.
15.1.2 Restrictive conditions
DST time span cannot exceed 10 months for a single DST.
DST time span cannot be less than 1 day for a single DST.
15.2 TOU
Support 4 tariffs.
Support maximum 50 holidays.
Holidays can be divided into two types: special yearly holiday and public yearly holiday. Special
yearly holidays only work only in specific years, while public yearly holidays work through the
current and future years.
Its available to set maximum 6 season tables which can be configured for one year, and under
each season table can set corresponding week table.
Maximum of 8 weekly timetables can be configured, and each weekly time table supports
separate configuration of daily timetable from Monday to Sunday.
Maximally 8 daily timetables can be configured, and each daily timetable supports
configuration up to 8 time periods. Configuration crossing zero is also available.