41
814 – Total import active power of current month: 1.10kWh
815 – The date of last recharging: 19/July/2012
816 – The time of last recharging: 21:35:15
817 – The credit of last recharging: 100.00kWh
818 – The return code of cancelation: please refer to the detailed depict
819 – The times of power off: 7 times
820 ~ 825 – Total import active energy of last 1 to 6 months: please refer to the detailed
list
830 ~ 839 – Last 1 to 6 recharging tokens
865 – Enter to the working mode
866 – Measurement accuracy test: the meter always shows the tested energy, the
accuracy increase 1 position up to Wh and calculated from 0. Re-stroke 866 or re-power,
the meter will exit the test mode