CHAPTER 6
Troubleshooting
64 Studio Command Series User Manual
EMEM
DINV
The fixture lost the display invert setting and
will default to non-inverted
To restore display invert setting, see
Inverting LED Characters (D/IN) on page
28.
EMEM
DLOS
The fixture lost the DMX data loss setting and
will default to short mode.
To reassign the DMX data loss setting, see
Data Loss Shutter Close (DLOS) on page
29).
EMEM
DPLY
The fixture lost the display setting and will
default to on and bright.
To restore the display setting, see
Changing
the Display Output (DSPL)
on page 28.
EMEM
FHRS
The fixture lost the number of fixture hours
and will default to zero.
Not Applicable.
EMEM
LHRS
The fixture lost the number of lamp hours and
will default to zero (700 model only).
Not Applicable.
EMEM
LMPL
The fixture lost the lamp life limitation setting
and will default to unlimited lamp life.
(700 model only)
If the fixture was set to lamp life limitation,
reassign the lamp life setting (see
Setting the
Lamp Warning Message (LMPL)
on page 29).
EMEM
L/ST
The fixture lost the number of lamp strikes and
will default to zero (700 model only).
Not Applicable.
EMEM
MODE
The fixture lost the mode setting (DMX control
or preset playback) and will default to DMX
control.
To reassign the mode setting, see
Setting
Preset Playback (PLAY)
on page 23.
EMEM
PINV
The fixture lost the pan invert setting and will
default to non-inverted.
To reassign the pan invert setting, see
Inverting Pan (P/IN) on page 27.
EMEM
SWAP
The fixture lost the pan/tilt swap setting and
will default to non-swapped.
To enable pan/tilt swap (see
Swapping Pan
and Tilt (SWAP)
on page 26).
EMEM
TINV
The fixture lost the tilt invert setting and will
default to non-inverted.
To reassign tilt invert setting (see
Inverting
Tilt (T/IN)
on page 27).
EMEM
TMOD
The fixture lost the test mode setting (Factory
Use Only) and defaults to normal operation.
Not Applicable.
EMEMU
SER
The fixture lost the assigned user setting and
will automatically default to user A.
To reassign the user setting (see
Setting the
User Type (USER)
on page 30).
ERSE
FLSH
One or more fixtures on the data link has
failed to erase the FlashROM in a suitable
amount of time.
Attempt another software crossload (see
Crossloading Fixture Software (XLD) on
page 32).
Contact High End Systems customer support
if problem continues.
Display
Message
Problem Solution