Storage System User Manual
19
HDD Detection
3. Select the Detection Mode as Rapid or Comprehensive.
Rapid: Detect parts of all HDD blocks. It takes shorter time than Comprehensive.
Comprehensive: Detect all HDD blocks. It takes longer time than Rapid.
It is recommended to operate rapid detection when system is under low pressure.
You are recommended to operate comprehensive detection for the first use HDD.
To keep data safe, detect an HDD every 3 months.
4. Click Start to start detecting. The selected detection mode, detection progress, and detection time are listed
in the top part of the interface.
5. Optionally, click Refresh to update the detection status, detection process and detection time.
Or you can click Stop to end all detections.
Table 3. 3 Detection Status Description
Check Status
Description
Uncommitted
HDD detection has not been committed.
Detecting
HDD is being detected.
Waiting
Another HDD is being detected. You need to wait till the detection is finished.
3.2 Array
Purpose:
You can create and manage array.
Step:
Click Storage in navigation bar and choose Array.