6. Check Target of Interest (Human Body) to discard non-human body pictures and videos which
are not triggered by human body detecon. The feature is only available for local human body
detecon.
7. Set detecon area.
Figure 7-15 Human Body Detecon
1) Select the detecon area to congure from the Area drop-down list. Up to 8 detecon areas
are selectable.
2) Check Enable Area to enable the selected
detecon area.
3) Edit the area name in Scene Name. The scene name can contain up to 32 characters.
4) Click Draw Area to draw a quadrilateral in the preview window and then click Stop Drawing.
8. Set the arming schedule. Refer to
Congure Arming Schedule .
9. Set linkage
acons. Refer to Congure Linkage Acons .
10. Click Apply to acvate the sengs.
7.5.2 Human Body Search
Search by Human Body Event
Search pictures by human body detecon alarms.
Steps
1. Go to Smart Analysis → Smart Search → Human → Search by Event .
2. Set the start
me and end me.
3. Select a channel.
4. Select Event Type as Human Body Alarm.
5. Click Start Search. The search result list displays 1 channel.
Network Video Recorder User Manual