Note
The supported number of relays varies with dierent models. Relay 1 corresponds to the 1A and
1B of the terminal. Relay 2 corresponds to the 2A and 2B of the terminal.
4.
Set the barrier gate operaon and alarm operaon for the temporary vehicles, vehicles in the
blocklist, and vehicles in the allowlist.
-
Check Upload via SDK to arm and upload the vehicle informaon to the arming terminal via
SDK.
-
If the device has been connected to the alarm device, check Upload to Alarm Host. When the
barrier gate is open, the alarm device will be triggered to alarm.
-
Check Upload to Mailbox to email the vehicle informaon to the user.
5.
Oponal: You can click Close, Open, Unlock, or Lock to control the barrier gate remotely.
Note
The funcons of remote control of barrier gate vary with dierent models. The actual device
prevails.
6.
Click Save.
1.8.3 Set Wiegand Parameters
The barrier gate can be connected to the device via Wiegand interface.
Steps
1.
Go to Conguraon → Capture → Entrance and Exit → Wiegand Parameters .
2.
Check Enable.
Figure 1-31 Set Wiegand Parameters
3.
Select Communicaon Direcon.
Send
The barrier gate can be connected to the device via Wiegand 26 or Wiegand 34 mode.
4.
Select Wiegand Mode.
5.
Click Save.