Page 12
MICRO-SPEED FUNCTION
Micro-speed is designed to temporarily restrict the speed of the hoist to a lower speed and to prevent high speed operations until the
function is released. The micro-speed function can be configured two ways.
2-STEP MAINTAINED MODE
– This mode will switch to a 2-Step maintained speed set. This is helpful where the micro-speeds need to
be specific. This mode can also be used to provide a single speed by setting the low and high micro speed values the same value. To
use this mode UE-16 must have a value of 0.
PERCENTAGE MODE
– This mode will take the value from UE-16 as a percentage of the standard speed set. Setting UE-16 to a value of
thod.
In the chart below the digital input 4 is configured from the factory for micro-speed.
Digital Input 4 Mirco-Speed Activation Input
CA-04 89:MI4
UE-10 500 (5.00 Hz)
UE-15 1000 (10.00 Hz)
UE-16
Value = 0 (2-STEP MAINTAINED MODE)
Value > 0 (PRECENTAGE MODE)
LIMIT TO 1
ST
SPEED FUNCTION
st
function. This is typically used for travel limits or when approaching an upper / lower hook limit. The parameter chart below
references setting digital input 6 but any available inputs other than input 7 can be used.
CA-06 96:MI11
Digital Input 6 Contact Status CA-26