TROUBLESHOOTING E001 / E005 / E039 FAULTS
WHAT IS AN E001, E005, and E039 FAULT The 3 faults are all over-current type faults.

secure.


the inverter.
When the current grows rapidly, [E001] excessive current error could occur before [E005] motor electronic thermal error.
Even if the electronic thermal level is set high, the electronic thermal for inverter works separately 

Check to see if the motor brake is releasing correctly.
Check if parameter bC110 value is set to lower than the over-weight value or 


Check motor wiring.
Contact Detroit Hoist for further assistance.
TROUBLESHOOTING E006 FAULT
WHAT IS AN E006 FAULT An E006 fault is a dynamic braking overuse fault. This means the dynamic braking usage ratio was
exceeded or met.
If the status of the fault was while at STOP then this typically points to the input power to the VFD increased for a long
-bus voltage level. Check the incoming power for
spikes or if l If this is the case, then try adding a line reactor in front of
the main power of the crane.
If the status of the fault was during RUN and the hoist has a load brake, then the load brake needs to be serviced. The VFD’s

dynamic braking

Contact Detroit Hoist for further assistance.