SETTING ENCODER-BASED LIMITS (CLV)
Use the step chart below to set the encoder-based limits. If using switches from the factory use the image below of the blue terminal
knife disconnect as reference.
Verify the encoder-based limits are enabled by navigating to VFD parameter UE-33 and verifying the value is set
to 1 or 2.
If you are using external switches (UE-33 = 1) then use the steps WITHOUT the asterisk *.
If you are using the parameters (UE-33 = 2) then use the steps with the asterisk *
Using Switches (UE-33 = 1)
Locate the blue terminal knife disconnect labeled “PP” and pull the yellow tab to the open position, this will put the
limits into program mode.
Run the hook block to the desired upper limit position and wait for the motor brake to set.
Locate the blue terminal knife disconnect labeled “PR” and pull the yellow tab to the open position and
wait 2 seconds then close the “PR” tab, this will clear the current position pulse count.
Run the hook block to the desired lower limit position and wait for the motor brake to set.
Close the yellow tab on the “PP” terminal knife disconnect.
Verify operation of the upper and lower limits.
* Using Parameters (UE-33 = 2)
Navigate to VFD parameter UE-66 and set the value to 1 and save it.
Run the hook block to the desired upper limit position and wait for the motor brake to set.
Navigate to VFD parameter UE-66 and set the value to 2 and save it, wait 2 seconds, and change it back to 1. This will
clear the current position pulse count.
Run the hook block to the desired lower limit position and wait for the motor brake to set.
Navigate to VFD parameter UE-66 and set the value to 0 and save it.
Verify operation of the upper and lower limits.
Encoder Limits Program and Reset Knife Disconnect