Scanreco G2 radio remote control system
HMF Technical Service Department
Troubleshooting by means of the CGW 5355
When the fault monitoring of the radio controller registers an error, and error codes are indicated
as stated above, data with the error code are transmitted to the RCL 5300 controller, saving the
error code in an error log in the black box.
By means of the CGW 5355 service terminal it is possible to read the error code from the black
box.
Example of indication of error codes:
Date, hour and minute when the error occurred
171 - Error code as indicated on the RCL 5300 display
0202 - Error code in the LED display in the radio
controller.
The RCL saves up to 50 different error types
In connection with troubleshooting, it is possible by means of the CGW 5355 to read the specific
type of error without having to remove the cover of the radio controller.
In the table below you see the interconnections between the error codes. Furthermore there is an
explanation of the type of error, the reason for the error, if any, as well as what can be done to
remedy the error.
display
in G2
the RCL 5300
description
in EEPROM
starting up is
incorrect.
mode. Restart the
system. Please contact
in FLASH
FLASH memory is
incorrect.
mode. Restart the
system. Please contact
execution of
in the software.
the CAN open
protocol, incorrect
data flow or overflow
automatic reset. Please
contact HMF Technical
Service.
hardware
hardware
identification.
automatic reset. Please
contact HMF Technical