Scanreco G2 radio remote control system
HMF Technical Service Department
Set-up, PWM control of the crane functions
In the table below is indicated an example of setting up a radio remote control system consisting
of:
- Hydrocontrol control valve with 6 functions.
- NEM electric activations for 6 crane functions.
- Dump valve (DMP 1) in the inlet section of the control valve.
- Scanreco G2 radio remote control.
The RCL 5300 software must be version 29_20 or higher.
The example is a standard set-up for cranes configured with the above-mentioned system.
Depending on the equipment, there may be used other output terminals in the radio controller.
Please also see the chapter "Description of Scanreco G2 parameters in the CGW 5355" and
"Setting up of output signals by means of the CGW 5355" as well as the electric diagram:
NEMRC, G2.
Description of the function
1.1.1.1.3.17 - Remote control
- Activate the feature Remote control.
1.1.1.1.1.17 - Remote control
- Set up the parameters in the Remote control menu.
- Select Scanreco V2 by means of the arrow key,
ENT.
- Radio controller, serial no. is not indicated.
1.1.1.1.1.17.4 - Recei. SN
- Radio receiver, serial no. is not indicated.
1.1.1.1.1.17.5 - Trans. SN
- Radio transmitter, serial no. is not indicated.
1.1.1.1.1.17.6 - Lever number
- State number of lever functions, ENT.
- Activate the feature - Display - if the remote control
box has a display fitted.
- Activate the feature PWM Mixer.
- Setting up in PWM Mixer.
- Setting up of crane functions.
1.1.1.1.1.25.2.1 - Max Current
- Select the current intensity to 650 mA at 24 volt.
- Select the current intensity to 1400 mA at 12 volt.
1.1.1.1.1.25.2.2 - Start Kick
- Select increased starting current to 20 %.
1.1.1.1.1.25.2.3 - Frequency
- Select the carrier frequency at 200 Hz.
1.1.1.1.1.25.2.4 - Dither Freq
- Select the superposed carrier frequency at 70 Hz.
1.1.1.1.1.25.2.5 - Source
- Setting up the crane functions on the outputs of the
radio controller.
1.1.1.1.1.25.2.5.1 - 1A, K1.1
- "Slew-right" on output terminal K1.1: Slew
1.1.1.1.1.25.2.5.2 - 1B, K1.3
- "Slew-left" on output terminal K1.3: Slew
1.1.1.1.1.25.2.5.3 - 2A, K1.5
- "Boom-down" on output terminal K1.5: Boom
1.1.1.1.1.25.2.5.4 - 2B, K1.7
- "Boom-up" on output terminal K1.7: Boom
1.1.1.1.1.25.2.5.5 - 3A, K1.9
- "Jib-up" on output terminal K1.9: Jib
1.1.1.1.1.25.2.5.6 - 3B, K1.11
- "Jib-down" on output terminal K1.11: Jib
1.1.1.1.1.25.2.5.7 - 4A, K1.13
- "Extension - out" on output terminal K1.13:
Extension
1.1.1.1.1.25.2.5.8 - 4B, K1.15
- "Extension - in" on output terminal K1.15:
Extension
1.1.1.1.1.25.2.5.9 - 5A, K3.1
- "Rotator-right" on output terminal K3.1: Rotator
1.1.1.1.1.25.2.5.10 - 5B, K3.3
- "Rotator-left" on output terminal K3.3: Rotator
1.1.1.1.1.25.2.5.11 - 6A, K3.5
- "Grab-open" on output terminal K3.5: Grab
1.1.1.1.1.25.2.5.12 - 6B, K3.7
- "Grab-close" on output terminal K3.7: Grab