In the table below is indicated an example of setting up a radio remote control system consisting
of:
- Hydrocontrol control valve with 6 functions.
- NEM electric activations for 6 crane functions.
- Dump valve (DMP 1) in the inlet section of the control valve.
- Scanreco G2 radio remote control.
The RCL 5300 software must be version 29_20 or higher.
The example is a standard set-up for cranes configured with the above-mentioned system.
Depending on the equipment, there may be used other output terminals in the radio controller.
Please also see the chapter "Description of Scanreco G2 parameters in the CGW 5355" and
"Setting up of output signals by means of the CGW 5355" as well as the electric diagram:
NEMRC, G2.
Menu item in CGW 5355
Configuration
Description of the function
1.1.1.1.3.17 - Remote control
Press ENT
- Activate the feature Remote control.
1.1.1.1.1.17 - Remote control
ENT
- Set up the parameters in the Remote control menu.
1.1.1.1.1.17.1 - Type
SET
- Select Scanreco V2 by means of the arrow key,
ENT.
1.1.1.1.1.17.2 - RF.Adr
-
- Radio frequency 0.
1.1.1.1.1.17.3 - Ebox SN
-
- Radio controller, serial no. is not indicated.
1.1.1.1.1.17.4 - Recei. SN
-
- Radio receiver, serial no. is not indicated.
1.1.1.1.1.17.5 - Trans. SN
-
- Radio transmitter, serial no. is not indicated.
1.1.1.1.1.17.6 - Lever number
SET
- State number of lever functions, ENT.
1.1.1.1.3.11 - Display
ENT
- Activate the feature - Display - if the remote control
box has a display fitted.
1.1.1.1.3.25 - PWM Mixer
ENT
- Activate the feature PWM Mixer.
1.1.1.1.1.25 - PWM Mixer
ENT
- Setting up in PWM Mixer.
1.1.1.1.1.25.2 - PWM
ENT
- Setting up of crane functions.
1.1.1.1.1.25.2.1 - Max Current
SET, type 650
- Select the current intensity to 650 mA at 24 volt.
SET, type 1400
- Select the current intensity to 1400 mA at 12 volt.
1.1.1.1.1.25.2.2 - Start Kick
SET, type 20
- Select increased starting current to 20 %.
1.1.1.1.1.25.2.3 - Frequency
SET, type 200
- Select the carrier frequency at 200 Hz.
1.1.1.1.1.25.2.4 - Dither Freq
SET, type 70
- Select the superposed carrier frequency at 70 Hz.
1.1.1.1.1.25.2.5 - Source
ENT
- Setting up the crane functions on the outputs of the
radio controller.
1.1.1.1.1.25.2.5.1 - 1A, K1.1
SET, arrow down
- "Slew-right" on output terminal K1.1: Slew
1.1.1.1.1.25.2.5.2 - 1B, K1.3
SET, arrow down
- "Slew-left" on output terminal K1.3: Slew
1.1.1.1.1.25.2.5.3 - 2A, K1.5
SET, arrow down
- "Boom-down" on output terminal K1.5: Boom
1.1.1.1.1.25.2.5.4 - 2B, K1.7
SET, arrow down
- "Boom-up" on output terminal K1.7: Boom
1.1.1.1.1.25.2.5.5 - 3A, K1.9
SET, arrow down
- "Jib-up" on output terminal K1.9: Jib
1.1.1.1.1.25.2.5.6 - 3B, K1.11
SET, arrow down
- "Jib-down" on output terminal K1.11: Jib
1.1.1.1.1.25.2.5.7 - 4A, K1.13
SET, arrow down
- "Extension - out" on output terminal K1.13:
Extension
1.1.1.1.1.25.2.5.8 - 4B, K1.15
SET, arrow down
- "Extension - in" on output terminal K1.15:
Extension
1.1.1.1.1.25.2.5.9 - 5A, K3.1
SET, arrow down
- "Rotator-right" on output terminal K3.1: Rotator
1.1.1.1.1.25.2.5.10 - 5B, K3.3
SET, arrow down
- "Rotator-left" on output terminal K3.3: Rotator
1.1.1.1.1.25.2.5.11 - 6A, K3.5
SET, arrow down
- "Grab-open" on output terminal K3.5: Grab
1.1.1.1.1.25.2.5.12 - 6B, K3.7
SET, arrow down
- "Grab-close" on output terminal K3.7: Grab