AG-21213-F-09-09 5
DE
GB
F
NL
A
2.1 LOCATION
Wall clearance is not required at the rear.
The lateral distance between machine and wall should be
400 mm on one side.
To avoid damage of the feet, do not slide the machine on floor after the
skid is removed.
Level machine by turning the feet.
Distribute machine weight equally onto all feet.
2.2 ELECTRICAL CONNECTION
Must be carried out by an authorized technician according
to the local and national codes.
The electrical supply shall comply with the name-plate data.
Line fuses and cable cross section shall comply with the requirements.
A cut-off device shall be provided to connect the supply cord (isolating
switch or accessible plug device).
According to EN 60 335 the appliance must be connected to an equipotential
conductor. The connecting screw (
) is located beside the cable inlet.
2.3 WATER CONNECTION
Must be carried out by an authorized technician according
to the national and local codes.
The machine must be operated with potable water. For water with
an extremely high mineral content an external demineralisation is
strongly recommended.
Machines without softener: Connect to soft and if possible warm
water (up to 4° Clark = 0.5 mmol/l, max. 60 °C).
Machines with softener: Connect to warm water (max. 60 °C) if
possible.
Machines with heat recovery (drain / exhaust): Connect to cold
water (min. 10 °C) if possible.
Line flow pressure 0.5 – 10 bar.
Important: the line flow pressure must not be less than 0.5 bar.
If the line flow pressure is above 10 bar provide pressure reducer
at source.
Connect the union nut "A" (
3
/
4
") of the water supply hose to the site
shut off valve.
Do not kink or cut the supply hose. If an extended supply hose is
required, use one of the same specifications as the original.