2.4 STEAM CONNECTION (STEAM HEATED MACHINES
ONLY)
Must be carried out by an authorized technician according
to the local and national codes.
Connection to steam supply (DN 20),
0.5 - 3.5 bar (max. 150°C) at the machine. See data plate!
Dimension of steam and condensate piping has to be according to the
requirements.
The machine is equipped with all necessary fittings.
Make sure that permissible pressures and temperatures will not be
exceeded.
All pipework has to be insulated with water and heat resistant material.
2.5 ADJUSTMENT OF SHUT-OFF VALVE FOR STEAM
SUPPLY
The built-in shut-off valve is equipped with an adjustment device (A) to
limit the steam flow rate. A special tool is necessary for
adjusting the valve-seat.
The correct adjustment is very important particularly for higher pres-
sure, and therefore must be done by a HOBART trained service techni-
cian at first installation or after any changes are done at the customer
site.
The adjustment is correct if the heating-up time of the boiler is as long
as the shortest wash cycle, while the valve is opened to maximum.
If adjusted too far open pressure shocks may occur when the solenoid
valve closes. This could cause damage at the installa tion. If adjusted
too far close the required heating-power cannot be achieved.
2.6 DRAIN CONNECTION
Connection between machine and site drain must not exceed max.
height of 0.80 m.
Do not place the drain hose loosely on the floor (the hose could be
rubbed through). Fix it at site!
Do not kink the drain hose.
30°-45°
max. 800 mm