EasyManua.ls Logo

Hobart UX Series - Fault Codes and Solutions

Hobart UX Series
20 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
AG-21213-F-09-09 17
DE
GB
F
NL
The Service indicator
Ç
illuminates and the temperature
indicator Rinse
Å
displays a code: e.g. "AL" = drain fault.
Possible types of fault as follows (please report the code of fault
to the service technician).
CODE
POSSIBLE CAUSE MEASURES
FIL
Shut-off valve is closed. Open shut-off valve at site and switch on machine again.
Fill valve or fill system defective.. Call the after sales service.
FIL +
Exceeded fill time. Call the after sales service.
AL
Drain hose blocked. Clean drain hose and restart drain cycle.
Drain system defective. Call the after sales service.
UL
Drain hose blocked. Clean drain hose and restart drain cycle.
Fill system or drain system defective Call the after sales service.
F01
Temperature probe "rinse booster" defective. Call the after sales service.
F02
Temperature probe "tank" defective.. Call the after sales service.
HEI
Rinse booster heating defective. Maybe restricted operation possible – call the after sales
service.
Flashing
BLUE/RED
Start button
Wash tank filters blocked. Remove and flush scrap basket and tank strainer.
Replace in machine, close door and press start button to
recommence wash cycle.
13 FAULTS