Programming
The menu in Programming Mode is to adjust settings, and calibrate sensors. It has the following
submenus:
l Measurement
l Alarms
l Datalog
l Wireless
l Monitor
l Calibration
Enter Programming in Basic Mode
Programming in Basic Mode is limited to calibration only. A password is required to access
other programming menus.
1. To enter Programming Mode, press and hold [MODE] and [N/-] until you see the
Password screen.
2. Input the 4-digit password:
l Increase the number from 0 through 9 by pressing [Y/+].
l Step from digit to digit using [N/-].
l Press [MODE] when you are done.
AreaRAE 50 User Manual

Table of Contents

Other manuals for Honeywell AreaRAE Plus

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Honeywell AreaRAE Plus and is the answer not in the manual?

Honeywell AreaRAE Plus Specifications

General IconGeneral
WirelessYes
Operating Temperature-20°C to 50°C (-4°F to 122°F)
Sensor TypeElectrochemical, catalytic bead, PID
Gases DetectedOxygen (O2), Combustible gases (LEL), Hydrogen Sulfide (H2S), Carbon Monoxide (CO), VOCs
Wireless ProtocolBluetooth
Display TypeLCD
PumpInternal pump
AlarmsVisual, audible, and vibration
Gas SensorsLEL, PID
Humidity Range10% to 95% RH (non-condensing)