Known issues
gtap.genetec.com | Honeywell Galaxy Control Panel Integration Guide 5.2 7
EN.550.007-V5.2.C4(3) | Last updated: March 11, 2014
Known issues
Galaxy Dimension control panel integration includes the following known issues.
Limitations
Galaxy Dimension control panel integration includes the following known limitations.
Issue Description
82756 Some intrusion detection events are not supported in Security Center 5.2.
Limitation Description
55922 If an input is triggered from Security Center (from triggered intrusion alarm or the
heartbeat monitoring feature), the input settings are overwritten with the values
configured in Security Center.
Wor ka ro un d: Make sure the input configuration is the same in Security Center as on
the control panel.
57661 The Galaxy Dimension control panel does not respond well to multiple input triggers
that occur within one second of each other. As a result, you may lose your connection to
Security Center.
Wor ka ro un d: Don’t trigger more than one input at a time.
56703 When you create custom events for the intrusion detection panel, the event list in the
Intrusion detection unit events task in Security Desk is not automatically updated.
Wor ka ro un d: Delete the Intrusion detection unit events task, and create a new task.
56828 Delay Arming (master/perimeter) is not supported.
57040 For some input functions such as "Final" and "Intruder", the Galaxy Dimension control
panel does not send notifications to Security Center when the input state changes from
"Normal" to "Active". Therefore, these inputs should not be used for virtual zones.
Please note that not all inputs functions have been tested, there may be others that
behave in the same manner.
57484 Offline logs are not supported.
57485 Security Center does not support the Galaxy configuration “Re-ordering of the on-
board RIO, SW3, dip-switch 8”.
57491 When an expansion module is connected or disconnected from the Galaxy Dimension
panel, you are not notified of the corresponding input and output states in Security
Center.
57492 The Intrusion Manager role cannot report the “Entry delay started” control panel event.

Table of Contents

Other manuals for Honeywell Galaxy Dimension series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Honeywell Galaxy Dimension series and is the answer not in the manual?

Honeywell Galaxy Dimension series Specifications

General IconGeneral
ModelGalaxy Dimension series
UsersUp to 250
PartitionsUp to 8
Operating Temperature-10°C to +55°C
CompatibilityHoneywell Galaxy accessories and peripherals