Preconfiguration checklist
gtap.genetec.com | Honeywell Galaxy Control Panel Integration Guide 5.2 17
EN.550.007-V5.2.C4(3) | Last updated: March 11, 2014
Configure the control panel for IP communication
If you want the Security Center server to communicate with the local Galaxy Dimension control
panel using IP communication, you must configure the Ethernet module E080-4
communication settings on the control panel.
For more information about configuring the Ethernet module, see your Honeywell
documentation.
NOTE If you are using RS-232 communication, you do not need to perform these steps. See
"Configure the control panel for RS-232 communication" on page 15.
Before you begin: Install the Honeywell Galaxy Ethernet module E080-4 with firmware
version 3.02.
1 Set the IP Address of the Ethernet module.
For more information about setting the module IP address, see “56.4.1.1 IP Address” in the
Honeywell Galaxy Dimension Installer Manual.
2 Set the alarm signalling Format as SIA, and the SIA level to level 4.
SIA level 4 allows Security Center to control the Galaxy Dimension control panel.
For more information about programming the SIA format, see “56.4.2.1 = SIA (0-4)
Security Industries Association” in the Honeywell Galaxy Dimension Installer Manual.
3 Using a keypad on your control panel, set the trigger event status to On.
4 Repeat step Step 3 for each trigger event.
5 Set the destination IP address and Port number of Security Center.
By default, the Security Center port number is 10002.
For more information about configuring the Primary IP’s IP address and port number, see
“56.4.2.2 - Primary IP” in the Honeywell Galaxy Dimension Installer Manual.
6 Create the Account Number (Account No.).
The account number must be a unique number that identifies the site. It can have up to six
digits.
Best practice: Do not start the account number with a zero.
For more information about creating an account number, see “56.4.2.4 - Account No.” in the
Honeywell Galaxy Dimension Installer Manual.
7 Using a keypad on your control panel, set the destination Receiver option to Single.
Selecting Single indicates that the Primary IP destination is used for signalling alarms.
For more information about setting the Receiver option, see “56.4.2.5 - Receiver” in the
Honeywell Galaxy Dimension Installer Manual.
8 Set the Protocol format to TCP (Transmission Control Protocol).
For more information about setting the protocol, see “56.4.2.8 - Protocol” in the Honeywell
Galaxy Dimension Installer Manual.
9 Configure the Remote access settings for the control panel.

Table of Contents

Other manuals for Honeywell Galaxy Dimension series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Honeywell Galaxy Dimension series and is the answer not in the manual?

Honeywell Galaxy Dimension series Specifications

General IconGeneral
ModelGalaxy Dimension series
UsersUp to 250
PartitionsUp to 8
Operating Temperature-10°C to +55°C
CompatibilityHoneywell Galaxy accessories and peripherals

Related product manuals