Preconfiguration checklist
gtap.genetec.com | Honeywell Galaxy Control Panel Integration Guide 5.2 18
EN.550.007-V5.2.C4(3) | Last updated: March 11, 2014
Set the Access period option to Any Time.
Setting the access period to Any Time allows Security Center to access the Galaxy
Dimension control panel at any time. For more information, see “56.4.3.1 - Access
Period” in the Honeywell Galaxy Dimension Installer Manual.
Set the access Mode to Direct Access.
Setting the Mode to Direct access allows Security Center to initiate the remote
connection with the control panel. For more information, see “56.4.3.2 - Mode” in the
Honeywell Galaxy Dimension Installer Manual.
10 For the SIA Control option, enter the IP address of the computer sending SIA events.
Set this option so the SIA controls sent from the control panel to Security Center are
recognized by the Ethernet module.
For more information about setting the SIA Control option, see “56.4.8 - SIA Control” in
the Honeywell Galaxy Dimension Installer Manual.

Table of Contents

Other manuals for Honeywell Galaxy Dimension series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Honeywell Galaxy Dimension series and is the answer not in the manual?

Honeywell Galaxy Dimension series Specifications

General IconGeneral
ModelGalaxy Dimension series
UsersUp to 250
PartitionsUp to 8
Operating Temperature-10°C to +55°C
CompatibilityHoneywell Galaxy accessories and peripherals

Related product manuals