gtap.genetec.com | Honeywell Galaxy Control Panel Integration Guide 5.2 38
EN.550.007-V5.2.C4(3) | Last updated: March 11, 2014
KSW CANCL Keyswitch Cancel BC-Burg Cancel, KSW CANCL-Keyswitch
Cancel
BJ-Burg Troub
rest
LOW RES Restor zone resistance BJ-Burg Troub rest, -LOW RES-Restor zone
resistance
BR-Burglary Rest 24 HOURS 24 hour zone restored BR-Burglary Rest, -24 HOURS-24 hour zone
restored
ALARM EXT Alarm extend zone rest BR-Burglary Rest, -ALARM EXT-Alarm extend
zone res
ATM-1 ATM-1 zone restored BR-Burglary Rest, -ATM-1-ATM-1 zone restored
ATM-2 ATM-2 zone restored BR-Burglary Rest, -ATM-2-ATM-2 zone restored
ATM-3 ATM-3 zone restored BR-Burglary Rest, -ATM-3-ATM-3 zone restored
ATM-4 ATM-4 zone alarm BR-Burglary Rest, -ATM-4-ATM-4 zone alarm
EXIT Exit zone type restored BR-Burglary Rest, -EXIT-Exit zone type restored
INT ALARM Intruder Delay restored BR-Burglary Rest, -INT ALARM-Intruder Delay
restored
INTRUDER Intruder zone restored BR-Burglary Rest, -INTRUDER-Intruder zone
restored
MASK Mask zone restored BR-Burglary Rest, -MASK-Mask zone restored
PRT ENTRY Part entry zone restored BR-Burglary Rest, -PRT ENTRY-Part entry zone
restored
SEC FINAL Secure final zone rest BR-Burglary Rest, -SEC FINAL-Secure final zone
rest
SECURITY Security zone restored BR-Burglary Rest, -SECURITY-Security zone
restored
URGENT Urgent zone restored BR-Burglary Rest, -URGENT-Urgent zone
restored
T/O BURGL Entry timeout restore BR-Burglary Rest, -T/0 BURGL-Entry timeout
restore
VIBRATION Vibration zone restored BR-Burglary Rest, -VIBRATION-Vibration zone
restored
VIDEO Video zone restored BR-Burglary Rest, -VIDEO-Video zone restored
BT_Burg Troub LOW RES Low resistance on zone BT-Burg. Trouble, +LOW RES-Low resistance on
zone
SIA event
Event logged
on panel
Event description
logged on panel Custom event in Security Center

Table of Contents

Other manuals for Honeywell Galaxy Dimension series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Honeywell Galaxy Dimension series and is the answer not in the manual?

Honeywell Galaxy Dimension series Specifications

General IconGeneral
ModelGalaxy Dimension series
UsersUp to 250
PartitionsUp to 8
Operating Temperature-10°C to +55°C
CompatibilityHoneywell Galaxy accessories and peripherals

Related product manuals