WIRING
WIRING BASICS: CONFIGURATION 1
When using a thermostat with integrated
humidity control (such as VisionPRO IAQ
or Prestige):
A thermostat controls the fan and •
TrueSTEAM.Thecontrolwillnotallow
steam production unless the system fan
ison.
WireThermostatGtotheHVACsystemG •
asnormal.
Wire TrueSTEAM HUM terminals to the •
systemHUMterminals.
WIRING BASICS: CONFIGURATION 2
When using a humidistat separate from the
thermostat (such as H8908 or TrueIAQ):
The external humidity control does •
notmonitororcontrolthesystemfan.
TrueSTEAM must confirm that the fan has
powerbeforeallowinghumidity.
BreakthethermostatGtoHVACsystem•
Gconnection.WirethermostatGto
TrueSTEAMGT.WireTrueSTEAMGFto
HVACsystemG.
ThermostatGcallswillpassdirectly•
throughTrueSTEAM.Ifthissignalis
not present, and humidity is needed,
TrueSTEAMwillrelaypowerfromitsRT
terminaltoGFandouttoHVACsystem
Gtoensurethefanhaspowerfor
humiditycalls.
Thermostat with
Humidity Control
HVAC System
Tr ueSTEAM
1
HUM
HUM
2 3
R
C
M29617
Humidity Control
Thermostat
TrueSTEAM
HVAC System
HUM
HUM
R
G
GT
GGF
M29618
Note:Thisimageisnotacompletewiringdiagram.Itonlydepictsfanregulation.See
“Wiring the TrueSTEAM” on page 19.
Note:Thisimageisnotacompletewiringdiagram.Itonlydepictsfanregulation.See
“Wiring the TrueSTEAM” on page 19.