STEP THREE: Clean the Tank
Usetapwatertoushloosemineralsfromthetank:
Sedimentscreenattank’sbottomisremovable.•
Foramorethoroughcleaning,soaktankinwater•
withCLR
®
,LimeAway
®
orwhitevinegar.Then
rinseclean.
Tankisdishwashersafe.•
Donotusehydrocarbon-basedcleaners.•
Unplugthepowercordandcarefullyrubminerals
offoftheheatingelementandtankwalls.Clearthe
sensorcompartmentholesofdebris,ifpresent.
STEP FOUR: Replace the Water Level Sensor (if necessary)
WARNING: Electrocution Hazard.
TrueSTEAM must be unplugged before removing the cover. Hazardous voltage could cause
death or serious injury.
RemoveTrueSTEAMcoverandinspectwater
levelsensor.Ifdebrisbuildupispresent,replace
thesensor(seebelow).
RemoveT-30Torxscrewandliftclamp.
Removethesensor.
Ensuresensorgasketsareseatedproperlyandarein
goodcondition(nocracks).
Installanewsensorifexcessivemineraldepositsare
present,orifgasketsareinpoorcondition.See “Parts
List” on page 35.