APPENDICES
TrueSTEAMHumidicationSystem69-2285EF—01
34
Humidifying Capacity
HM506:upto6gallonsperday(gpd)
(23 liters per day [lpd])
HM509:upto9gpd(34lpd)
HM512:upto12gpd(45lpd)
Humidified Area
HM506:4,000–14,400cubicfeet
HM509:8,000–18,400cubicfeet
HM512:12,000–24,000cubicfeet
Note:HighervolumesrequiremoreTrueSTEAMruntime.
Weight
Empty Filled with Water
HM506: 8lbs. 12lbs.
HM509: 8lbs. 15lbs.
HM512: 9lbs. 15lbs.
Dimensions
11-1/4in.Wx19in.Hx9in.D
Operating Temperature Range
TrueSTEAMHumidier:34ºF–104ºF(1.1ºC–40ºC)•
RemoteHose/Nozzle:-50ºF–250ºF(-46ºC–121ºC)•
OperatingHumidityRange:0–95%RH,non-condensing•
Drain Operation
AutomaticFlushSchedule:Congurableto8,12,20,or•
30 hours of operational time (heating element active)
AutomaticFlushCycleTime:Flushcycletakes•
approximately45minutestoemptythetankcompletely
DrainingTemperatureRange:34ºF–212ºF(1.1ºC–100ºC)•
Electrical Ratings and Tolerances
Input Ratings
• PowerSupply:120VAC+10-15%,60Hz
-HM506:840Wat120VACatfullload
-HM509:1200Wat120VACatfullload
-HM512:1440Wat120VACatfullload
• HM506:7A,120VAC
• HM509:10A,120VAC
• HM512:12A,120VAC
• 15A,120VACinterlockswitch
• Thermostat/HVACpowermonitor(RtoC):
10mAresistiveat24VAC
• Fieldwiringterminals:18–22ga.Solid
• HVACpower/airowmonitor:10mAresistiveat24VAC
Output Ratings
• Relayoutputcontacts:
-Fan:1.5Afullload,7.5Alockedrotorat24VAC
-Heatandbackup:15Aresistiveat120VAC
• FillSolenoid:0.1Aat120VAC,0.5PF
• DrainSolenoid:0.1Aat120VAC,0.5PF
• Humidistatoutputcontacts:10mAresistiveat24VAC
• Humidistatpowersupply:100mAat24VAC
Standards and Approval Body Requirements
UnderwritersLaboratories:UL998,Fileno.E185662•
FederalCommunicationsCommission:ClassB•
compliance,Fileno.YU555
Intendedtobeusedinaccordancewiththe •
NationalElectricalCode(NEC),ANSI/NFPA70,
andtherulesoftheCanadianElectricalCode(CEC),
Part1,C22.1
A: Specifications