Impact / Impact Pro / Impact Pro IR Operating Instructions
11
Instrument Labels
Neotronics Equipment Labels
An explanation of the information on the equipment label is shown below.
CAUTION:
Impact Unit Part No. 2302B1000XXX
Poole, Dorset
BH17 ORZ, UK
Comms Connection onlytoother certified
Impact detectorsin hazardous area
Read and understand instruction manual before
operatingor servicing
Replace/Recharge batteries onlyin Non Hazardous area
Refer to Manual for battery types
Manufacturers Name and Address
User Cautions
Honeywell Analytics Ltd.
Neotronics CENELEC (ATEX) Certification Label
An explanation of the information on the CENELEC (ATEX) certification label is
shown below.
Neotronics Impact Pro non-IR Label:
Product Name
Explosion Protection Mark
and Equipment Group
Category
Certified Ambient
Temperature Range
EU Explosive Atmosphere
Symbol and Certification Code
as EN50014:1992
DMT Approval
CE Mark - Conforms
to all EC Directives
Identification No. of AT EX
Notified Body
Brazilian
Approval
Australian Mines
Approval
Australian
Surface Approval
Certification Number
IMPACT GAS DETECTOR
Maritime Equipment Directive
Inmetro Approval
This instrument has been assessed by EXAM (formerly DMT) for performance
of Oxygen, Methane, Propane, Carbon Monoxide, Hydrogen Sulfide and Carbon
Dioxide (electrochemical cell only) channels.
The label marking indicates this: DMT 02 ATEX G 001
PFG Nr. 41300502
The instrument has been tested in accordance to the following European
Standards.
EN50• 054 & EN50057: 1998 for Combustible Gases (Methane and
Propane).
EN50104: 2002 for the measurement of Oxygen.•
EN45544-1 & EN45544-2: 1999 for the measurement of Carbon Monoxide, •
Hydrogen Sulfide and Carbon Dioxide (electrochemical cell only).
EN50271: 2000 for the assessment of Digital Components and •
Software.
MED: Maritime Equipment Directive•