EasyManuals Logo

Honeywell Impact Series User Manual

Honeywell Impact Series
84 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #80 background imageLoading...
Page #80 background image
Impact / Impact Pro / Impact Pro IR Operating Instructions
80
B�3 Technical Specifications
B�3�1 Instrument Specification
Weight 520g (18oz) including rechargeable battery packs and pump
Dimensions 49mm x 84mm x 136mm (1.9” x 3.3” x 5.3”)
Electrochemical/
Catalytic Sensors
Range Repeatability
Response
Time (T90)
Warm-up
Time (s)
Impact
Impact
Pro
Flammable
Methane
Oxygen
Carbon Monoxide
Hydrogen Sulde
Sulfur Dioxide
Chlorine
Chlorine Dioxide
Nitrogen Dioxide
Ammonia
Carbon Dioxide
0 to 100% LEL
0 to 5% v/v
(Displayed as %LEL)
0 to 25% v/v
3 to 500 ppm
(Display: 0-500 ppm)
0.4 to 50 ppm
(Display: 0-50 ppm)
0 to 20 ppm
0 to 10 ppm
0 to 5 ppm
0 to 20 ppm
0 to 100 ppm
0.2 to 2% v/v
(Display: 0-2% v/v)
±3% LEL
±0.1% v/v
±0.3% v/v
±12.5 ppm
±2.5 ppm
±1 ppm
±0.5 ppm
±0.2 ppm
±1 ppm
±5 ppm
±0.2% v/v
See B.3.3
<10s
See B.3.3
See B.3.3
See B.3.3
<60s
<60s
<60s
<60s
<90s
See B.3.3
70
70
70
70
70
70
70
70
70
250
70
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
Infrared Sensors Range Repeatability
Response
Time (T90)
Warm-up
Time (s)
Impact
Impact
Pro
Flammable (%LEL)
Flammable (%Vol)
Carbon Dioxide
0 to 100% LEL
0 to 100% v/v
0 to 5% v/v
70
70
70
3
3
3
Visual alarm 4 High intensity red LEDs (alarms, fast charge indication)
2 High intensity green LEDs (condence signal, trickle charge indication)
Audible alarm >85dBA at 1m (>90dBA at 1ft)
Display Large backlit graphical liquid crystal display
IP Rating Instrument IP67 (NEMA 4X), Cartridge IP54 (NEMA 4)
Operating temperature -20°C to +55°C (-°4F to +131°F)
Carbon Dioxide: 0°C to +40°C (+32°F to +104°F)
Ammonia: -20°C to +40°C (-°4F to +104°F)
Storage Temperature
& Time
Instrument, spare parts and accessories:
-40°C to +80°C (-40°F to +176°F)
Cartridge and replacement sensors:
-10°C to +60°C (+14°F to +140°F) 6 months maximum
Electrochemical Carbon Dioxide Cartridge and replacement sensors:
-10°C to +40°C (+14°F to +104°F) 6 months maximum
Ammonia Cartridge and replacement sensors:
-10°C to +40°C (+14°F to +104°F) 6 months maximum
Pressure 800mBar to 1200mBar
Carbon Dioxide Cartridge 910mBar to 1110mBar
Humidity 20 to 90% continuous (non-condensing)
Pump (where tted) 0.3 litres/minute over 20m (66’)
Flow fail detection and pump shutdown system under blocked ow
Test and Calibration routine of ow fail detection circuit
EMC Approvals EN50270
Internal Battery
(clock and memory)
>5 years operating life.

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Honeywell Impact Series and is the answer not in the manual?

Honeywell Impact Series Specifications

General IconGeneral
BrandHoneywell
ModelImpact Series
CategoryBattery Charger
LanguageEnglish

Related product manuals