SPZ--8000 Digital Integrated Flight Control System
A28--1146--055
REV 2
System Limits
7-8
Mode V a lueParameter
Control or
Sensor
V
O
R
C
r
s
k
V
O
R
T
r
:
V
O
R
C
ourse
k
no
N
A
V
V
O
R
T
rac
:
an
N
A
V
receiver
Roll angle limit 24_
17_ low bank switched
Roll rate limit 4.0 degrees/second
Crosswind Correction Up to 45_ course error
Overstation course
change
Up to 120_
Overstation roll angle
limit
24_
17_ low bank switched
VOR APP Same as VOR Same as VOR and flaps
0:
Roll an
le limit 30_
f
i
x
ed low bank
R
l
l
l
l
i
m
i
t
f
i
x
l
w
k
inhibited
Roll rate limit 7.0/second
APR or
B
C
Course knob
N
A
V
LOC Capture:
B
C
and N
A
V
receiver
Beam intercept angle
(HDG SEL)
Up to 90_
Capture point Function of beam, beam
closure rate, and course
error
Minimum trip point: 35 mV
dc
Maximum trip point: 200
mV dc
Roll angle limit 24_
Roll rate limit 7.0_/second
Course cut limit durin
45_ course
C
r
s
c
t
l
i
m
i
t
r
i
capture
c
r
s
System Performance and Operating Limits
Table 7--1 (cont)