System Limits
Mode V a lueParameter
Control or
Sensor
VFLC FMS MACH engage range Mach0.4to0.9
MACH hold error Mach 0.01
Pitch limit 20_
Pitch rate limit .3g maximum
IAS engage range 80 to 400 kts
IAS hold engage 5kts
Pitch limit 20_
Pitch rate limit .3g maximum
VPTH FMS Altitude range 0 to 60,000 feet
Angle range 0_ to --6_
Bias range f (FMS Waypoint)
Pitch limit 20_
Pitch rate limit .3g maximum
System Performance and Operating Limits
Table 7- -1