9.3.3 Pulse Width Measurement
In Pulse Width Measurement mode, the high-speed input can measure the width of a pulse
stream in one of two modes and provides a continuous indication of the last sampled value. In
this mode, the Disable and Latch special functions are allowed. Please see section 12.2 for a
description of these functions.
Width High 1μs Counts – In this sub-mode the accumulator value will contain the number of 1μs
counts the pulse is high.
Width Low 1μs Counts - In this sub-mode the accumulator value will contain the number of 1μs
counts the pulse is low.
Figures 9.1 - 9.2 - Pulse Width Measurements, High & Low
Width High
Width Low